Staged Update Rollout with Physical Regression Testing
Objective
Prevent updates (model, firmware) from introducing unsafe physical behavior.
Control / requirement
Staged rollout with mandatory physical safety regression testing before fleet-wide deployment.
Applicability
All physical AI systems receiving model, firmware, or software updates.
Expected evidence
Regression test results; staged rollout records. [T2/T3]
Assurance expectation
Evidence that regression testing specifically covers safety-critical behaviors, not only functional correctness.
Dependencies
PAI-SF-ACT-003 (actuator divergence monitoring) may detect update-induced behavior shifts post-deployment as a backstop.
Exclusions
Not applicable to fully air-gapped systems with no update mechanism.
Maturity / conformance relevance
Expected at Operational and High-Assurance levels.
Ecosystem relationship
Extends GAISSF™ change management to physical safety regression; provides update-related incident categories for UAIF™.